Technical details of the central control units in comparison

Central control unit model MV5 ZE 101 XL MV5 ZE 401 XL
Connections
Operating voltage range [VAC]: 90 - 264 90 - 264
Nominal frequency [Hz]: 47 - 63 47 - 63
Nominal current [A]: Max. 1,25 Max. 1,25
Digital inputs: 24, potential free 24, potential free
Digital outputs: 24 VDC / 0,5 A 24 VDC / 0,5 A
Accepted external tension for digital inputs: 24 VDC +/- 20% 24 VDC +/- 20%
Hardware
Plug-in card slots: 2 4
Interfaces: 2x USB-A, 1x USB-B, RJ45 2x USB-A, 1x USB-B, RJ45
Version without display: Sim, Model MV5 ZE 100 XL Não
Dimensions (without plugs): ca. 346 x 180 x 133 ca. 485 x 180 x 133
On / Off button: Não Sim
19" version: Sim, with angles Sim
Operation / Data input: MV5 ZE 101 XL: Integrated touch screen / USB-Keyboard MV5 ZE 100 XL: PC-Software Integrated foil keyboard / USB-Keyboard
IP54: Sim Sim
Communication
Power board, e.g. control of rotary axis (optional): Sim Sim
Communication cards (optional): Sprachdaten ergänzen(0)PROFINET CU/LWL, PROFIBUS, Ethernet TCP/IP (Rockwell) Sprachdaten ergänzen(0)PROFINET CU/LWL, PROFIBUS, Ethernet TCP/IP (Rockwell)
External power supply for communication cards (optional): Sim Sim
Ethernet TCP/ IP (optional): Sim Sim
Preconfigured PLC function module, e.g. TIA (optional): Sim Sim
I/O-card (optional): Sim Sim
Safety relay module (optional): Sim Sim
Software
Internal storage: Sufficient for several hundred marking files Sufficient for several hundred marking files
User password levels: Sim Sim
Preview function: Sim Sim
PC-Software (optional): Sim Sim
Logo marking (optional): Sim Sim
Data Matrix Code (optional): Sim Sim
CSV Import (optional): Sim Sim
WriteLog (optional): Sim Sim
FTP (optional): Sim Sim
MV5 ZE 101 XL
Connections
Operating voltage range [VAC]: 90 - 264
Nominal frequency [Hz]: 47 - 63
Nominal current [A]: Max. 1,25
Digital inputs: 24, potential free
Digital outputs: 24 VDC / 0,5 A
Accepted external tension for digital inputs: 24 VDC +/- 20%
Hardware
Plug-in card slots: 2
Interfaces: 2x USB-A, 1x USB-B, RJ45
Version without display: Sim, Model MV5 ZE 100 XL
Dimensions (without plugs): ca. 346 x 180 x 133
On / Off button: Não
19" version: Sim, with angles
Operation / Data input: MV5 ZE 101 XL: Integrated touch screen / USB-Keyboard MV5 ZE 100 XL: PC-Software
IP54: Sim
Communication
Power board, e.g. control of rotary axis (optional): Sim
Communication cards (optional): Sprachdaten ergänzen(0)PROFINET CU/LWL, PROFIBUS, Ethernet TCP/IP (Rockwell)
External power supply for communication cards (optional): Sim
Ethernet TCP/ IP (optional): Sim
Preconfigured PLC function module, e.g. TIA (optional): Sim
I/O-card (optional): Sim
Safety relay module (optional): Sim
Software
Internal storage: Sufficient for several hundred marking files
User password levels: Sim
Preview function: Sim
PC-Software (optional): Sim
Logo marking (optional): Sim
Data Matrix Code (optional): Sim
CSV Import (optional): Sim
WriteLog (optional): Sim
FTP (optional): Sim
MV5 ZE 401 XL
Connections
Operating voltage range [VAC]: 90 - 264
Nominal frequency [Hz]: 47 - 63
Nominal current [A]: Max. 1,25
Digital inputs: 24, potential free
Digital outputs: 24 VDC / 0,5 A
Accepted external tension for digital inputs: 24 VDC +/- 20%
Hardware
Plug-in card slots: 4
Interfaces: 2x USB-A, 1x USB-B, RJ45
Version without display: Não
Dimensions (without plugs): ca. 485 x 180 x 133
On / Off button: Sim
19" version: Sim
Operation / Data input: Integrated foil keyboard / USB-Keyboard
IP54: Sim
Communication
Power board, e.g. control of rotary axis (optional): Sim
Communication cards (optional): Sprachdaten ergänzen(0)PROFINET CU/LWL, PROFIBUS, Ethernet TCP/IP (Rockwell)
External power supply for communication cards (optional): Sim
Ethernet TCP/ IP (optional): Sim
Preconfigured PLC function module, e.g. TIA (optional): Sim
I/O-card (optional): Sim
Safety relay module (optional): Sim
Software
Internal storage: Sufficient for several hundred marking files
User password levels: Sim
Preview function: Sim
PC-Software (optional): Sim
Logo marking (optional): Sim
Data Matrix Code (optional): Sim
CSV Import (optional): Sim
WriteLog (optional): Sim
FTP (optional): Sim